免费国产成人AⅤ在线观看_国产成人久久综合热_色综合天天综合网国产成人网_一级毛片免费不卡在线

產(chǎn)品展示您的位置:網(wǎng)站首頁 > 產(chǎn)品展示 > 渦輪流量計(jì) > 柴油流量計(jì) > CPT84-AN-C-C06COX精密渦輪流量計(jì)

COX精密渦輪流量計(jì)

簡要描述:

COX精密渦輪流量計(jì)Cox Precision Turbine Flow Meters have unprecedented mechanical
linearity, resulting in minimizing, or negating, temperature induced
viscosity influence.

打印當(dāng)前頁

分享到:

COX精密渦輪流量計(jì)

Precision Meters Turbine Flow Meters DESCRIPTION Cox Precision Turbine Flow Meters have unprecedented mechanical linearity, resulting in minimizing, or negating, temperature induced viscosity influence. Cox Precision Turbine Meters come with a variety of process fittings, sizes and options to accommodate the requirements of most applications while offering wide flow ranges. Features Benefits Expanded Increased usable flow range with less mechanical linearity sensitivity to fluid temperature/viscosity effect on the output. APPLICATIONS Helical rotor design Exceptional speed-of-response, with reduced pressure drop. Cox Precision Flow Meters are the ideal solutions for standard and high pressure liquid flow applications in test and measurement and precision industrial processes, found in the automotive, aerospace and general industries. Comprehensive pickoff selection Meets application requirements for temperature and electronic outputs. High-Performance Ceramic bearings provide near-perfect ceramic ball bearings roundness, higher Rockwell hardness and are lighter and more tolerant to temperature than 440C stainless steel bearings. They eliminate adhesive wear and perform well in non-lubricating liquids found in cryogenic fluids and water. OPERATION AND PERFORMANCE As a fluid passes through the meter, the velocity of the fluid provides rotational energy on the rotor. The rotor blades, passing through a magnetic or radio frequency field, generate pulses proportional to flow. Each pulse is transmitted to the meter electronics, where it amplifies the pulse output. 6-bladed rotor supports NVLAP accredited facility with NIST traceable standards verify that all calibrators produce the same result. A variety of end fittings Improved flow conditioning. Outstanding mechanical linearity, up to 100:1, is achievable, depending on meter size. Paired with a flow processor, meter linearity improves from the standard ± 0.5 0 percent to within ± 0.1 percent of reading over the entire repeatable flow range, while providing fluid temperature viscosity compensation. Temperature effects on the meter bore diameter are compensated for by using thermal expansion coefficients, with Strouhal-Roshko equations, to provide a very accurate and repeatable volumetric flow rate. Third party audits to ensure calibration uncertainty. Laboratory correlation to AN, NPT, hose barb, flange, high pressure, tri-clamp and special fittings to meet specific installation configurations. Performance Speci?cations CALIBRATIONS Calibrations are accomplished by using various blends of solvent and oil to simulate actual fluid conditions. For varying process temperature conditions, multiple viscosity calibrations are used to develop a universal viscosity curve. UVC calibrations enable a flow computer to track temperature and compensate for fluid viscosity. Flow Dynamics tailors calibrations to replicate process conditions so the meter is characterized to provide the best attainable accuracy. • • • • • • Repeatability: ± 0.02% of reading Linearity: ± 0.5 0% (± 0.1% with flow processor) Calibrator Uncertainty: ± 0.05 % of reading Frequency Output: 1200…15 00 Hz Response Time: 2…3 ms (at 1.2 cSt) Pressure Ratings: See “Pressure Speci?cations” on page 5 Calibrations are performed by our Flow Dynamics NVLAP (Lab Code 200668) accredited calibration facility, which uses primary standard calibrators, offering uncertainties of ± 0.05 percent of reading with ± 0.02 percent repeatability. Users can be assured that Cox Precision Meters come with a best-in-class calibration, traceable to NIST standards.  Product Data Sheet TUR-DS-00169-EN-02 (September 2013) Precision Turbine Flow Meters CONSTRUCTION METER INSTALLATION Cox Precision Meters feature 316 stainless steel housings. Wetted materials include axial helical rotors, made of 17-4 stainless steel, that rotate on robust ceramic ball bearings. The supports and all other materials are made from 300 series stainless steel. High pressure meters come standard with AS33514 fittings. End Fittings are fully compliant with AS33514 and AS4375. For pressure ratings, see “Pressure Speci?cations” on page 5. Cox Turbine Flow Meters mount directly in the piping and can be installed in any position without affecting performance. For optimal performance, recalibrate the meter if the mounting orientation is changed from the original horizontal calibration. To reduce flow turbulence, a straightener section of tube, at a minimum of 10 diameters in length upstream and a similar section at a minimum of five diameters downstream, is recommended. If this recommendation is impractical, due to space limitations, pay careful attention to the location of valves and bends. To compensate for piping bends, meters can be calibrated in the same piping configuration. Flow straightener sections are available from Cox Flow Measurement. For best performance and longevity, upstream filtration (10...75 micron, depending on meter size) is helpful, to prevent bearing contamination and to avoid rotor blade damage. Materials of Construction Body 316 stainless steel 316 stainless steel 17-4 PH stainless steel Ceramic Shafts Rotors Bearing Page 2 September 2013 Product Data Sheet FLOW RANGE SPECIFICATIONS NOTE The flow data below represents two different pickoff types, radio frequency and magnetic. Radio frequency (RF) pickoffs extend the measurable linear flow range by eliminating magnetic induced drag. RF pickoffs require a power input, whereas magnetic pickoffs generate their own power to produce an output signal and typically, have greater tolerance to higher process temperatures. U.S. Standard Flow Data Carrier (RF) Linear Range 2 Non-Linear Repeatable Range Δp 1 at Max. Freq. Output at Max. Flow Linear Flow Ratio gpm (lpm) lb/hr (kg/hr) gpm (lpm) lb/hr (kg/hr) Flow Ratio (Turndown) Flow PSIG (g/cm2) Size 0.20…3.00 76…1143 0.05…3.00 19…1143 6.5 8-4 8-6 15:1 20:1 60:1 (0.76…11.36) (34.47…518.46) (0.19…11.36) (8.62…518.46) (0.46) 0.30…6.00 (1.14…22.71) 114…2286 (51.71…1036.91) 0.06…6.00 (0.23…22.71) 22.8…2286 (10.34…1036.91) 8.5 (0.60) 0.40…9.50 152…3619 0.09…9.50 34.3…3619 8.5 8 24:1 (1.51…35.96) (68.95…1641.55) (0.34…35.96) (15.56…1641.55) (0.60) 100:1 0.50…15.5 (1.89…58.67) 190…5905 (86.18…2678.46) 0.16…15.5 (0.61…58.67) 60.9…5905 (27.62…2678.46) 9.0 (0.63) 10 12 16 20 30:1 30:1 40:1 50:1 1.00…30.0 (3.78…113.56) 381…11,430 (172.82…5184.56) 0.30…30.0 (1.13…113.56) 114…11,430 (51.71…5184.56) 9.0 (0.63) 1500 Hz 1.60…65.0 (6.06…246.05) 610…24,765 (276.69…11,233.2) 0.45…65.0 (1.70…246.05) 171…24,765 (77.67…11,233.2) 9.0 (0.63) 1.90…95.0 (7.19…359.61) 724…36,195 (328.40…16,417.7) 0.65…95.0 (2.46…359.61) 247…36,195 (112.04…16,417.7) 8.5 (0.60) 150:1 2.60…155 (9.84…586.74) 990…59,055 (449.06…26,786.9) 1.05…155 (3.97…586.74) 400…59,055 (181.44…26,786.9) 9.0 (0.60) 24 60:1 3.10…310 (11.73...1,173.48) 1181…118,110 (535.69…53,573.7) 2.10…310 (7.95…1173.48) 800…118,110 (362.87…53,573.7) 9.0 (0.63) 32 100:1 NOTES: 1. Pressure drop is based on using MIL-PRF-17024E, Type II at 77° F, with a speci?c gravity of 0.77. 2. Linear ?ow range was developed using 1.2 centistokes. September 2013 Page 3 Precision Turbine Flow Meters Magnetic 10 1 Linear Range E xtended Range – Linear2 K-Factor Pulses/ Freq. at Min./Max. Output (Hz) Δp1 at 10 1 PSID gpm (lpm) lb/hr (kg/hr) gpm (lpm) lb/hr (kg/hr) Flow Ratio (Turndown) Size Gallon3 (kg/cm 2 ) (Liter3) 0.25…2.50 95…952 3.5 28,800 (7610) 0.25…3.00 95…1143 8-4 8-6 8 12:1 12:1 15:1 15:1 20:1 24:1 30:1 30:1 48:1 120/1440 120/1440 96/1440 96/1440 72/1440 60/1440 48/1440 48/1440 30/1440 (0.95…9.46) (43.09…431.82) (0.25) (0.95…11.36) (43.09…518.46) 0.50…5.00 (1.89…18.93) 190…1905 (86.18…864.10) 4.5 (0.32) 14,400 (3805) 0.50…6.00 (1.89…22.71) 190…2286 (86.18…1036.91) 0.75…7.50 (2.84…28.39) 285…2857 (129.27…1295.91) 6.0 (0.42) 9600 (2536) 0.60…9.00 (2.27…34.07) 229…3429 (103.87…1555.37) 1.25…12.5 (4.73…47.32) 476…4762 (215.91…2160.01) 5.0 (0.35) 5760 (1522) 1.00…15.0 (3.79…56.78) 381…5715 (172.82…2592.28) 10 12 16 20 24 2.50…25.0 (9.46…94.74) 952…9525 (431,82…4320.47) 5.0 (0.35) 2800 (761) 1.50…30.0 (5.68…113.56) 571…11,430 (259.01…5184.56) 5.00…50.0 (18.93…189.27) 1905…19,050 (864.09…8640.93) 5.0 (0.35) 1440 (380) 2.50…60.0 (9.46…227.13) 953…22,860 (432.27…10,369.1) 7.50…75.0 (28.39…283.91) 2857…28,575 (1295.91…12,961.4) 5.5 (0.39) 960 (254) 3.00…90.0 (11.36…340.69) 1143…34,290 (518.46…15,553.6) 12.5…125 (47.32…473.18) 4762…47,625 (2160.01…21,602.3) 6.0 (0.42) 576 (152) 5.00…150 (18.93…567.81) 1905…57,150 (864.09…25,922.8) 25.0…250 (94.64…946.35) 9525…95,250 (4320.47…43,204.6) 6.5 (0.46) 288 (76) 6.20…300 (23.47…1135.62) 2362…114,300 (1071.39…51,845.6) 32 NOTE S: 1. Pressure drop is based on using MIL-PRF-17024E, Type II at 77° F, with a speci?c gravity of 0.77. 2. Extended range is linear, with liquids up to 1.5 centistokes. Over 2.0 centistokes, output becomes non-linear but repeatable. 3. K-Factor will vary slightly from meter to meter. Page 4 September 2013 Product Data Sheet PRESSURE SPECIFICATIONS Pressure Ratings for AN End Fittings Meter Body 316 Stainless Steel 300° F Pipe Size Size 100° F 500° F in. (mm) bar psig 5330 4600 7000 5660 4600 3600 2760 2430 1760 bar 299 245 388 319 245 193 157 135 97 psig 4340 3550 5625 4630 3550 2800 2280 1965 1405 bar 231 172 293 248 172 138 124 103 72 psig 3350 2500 4250 3600 2500 2000 1800 1500 1050 8-4 8-6 8 10 12 16 20 24 32 0.25 (6.35) 0.37 (9.52) 0.50 (12.7) 0.62 (15.87) 0.75 (19.05) 1.00 (25.4) 1.25 (31.75) 1.50 (38.1) 2.00 (50.8) 367 317 483 390 317 248 190 168 121 Pressure Ratings for HP End Fittings Meter Size Continuous Proof Burst PSIG 5000 Bar 345 PSIG 7500 Bar 517 PSIG 25,000 Bar 1724 All Sizes Pressure Ratings for NPT End Fittings Meter Body 316 Stainless Steel Male (Furnished Thread) Female (Mating Thread) bar bar ISO/NPT Pipe Size Size in. (mm) psig 7614 7144 7050 6768 6768 4982 5828 4794 3760 psig 5922 4700 4418 4136 4136 4042 4700 4230 3666 8-4 8-6 8 10 12 16 20 24 32 0.25 (6.35) 0.37 (9.52) 0.50 (12.7) 0.75 (19.05) 0.75 (19.05) 1.00 (25.4) 1.25 (31.75) 1.50 (38.1) 2.00 (50.8) 525 493 486 466 466 343 401 330 259 408 324 305 285 285 278 324 291 253 NOTES: 1. Pressure ratings listed are for temperatures up to 100° F (37.8° C). 2. Pressure rating is calculated with an allowable stress value of 20,000 psi for 316 SS per pressure piping code ASME B31.3. 3. Chart is displaying safe working pressure, in accordance with power piping code ASME B31.1. NOTE It is recommended that the flow meter have “AN”end fittings and that the “NPT”transition be done on the far ends of the flow straighteners. This avoids a step in the flow stream next to the flow meter and produces an improved flow profile. If the NPT end fittings were selected for their high pressure rating, then the step is unavoidable and the calibration will account for the distorted profile. Pressure Ratings for Flange End Fittings (in accordance with ASME B16.5 Standards) ANSI Flange 150# PSIG 275 Bar 19 300# 720 50 600# 900# 1500# 2500# 1440 2160 3600 6000 99 149 248 414 NOTES: 1. Speci?cations from maximum non-shock allowable working pressure in PSIG at 100° F (37.8° C) or less. 2. Stainless steel 316A-181 material. September 2013 Page 5 Precision Turbine Flow Meters Pressure Ratings for Tri-Clamp End Fittings Pipe Size Meter Body 316 Stainless Steel Size in. (mm) bar 153 153 153 41 41 41 41 41 psig 2220 2220 2220 600 600 600 600 600 8-4 8-6 8 10 12 16 20 24 32 0.25 (6.35) 0.37 (9.52) 0.50 (12.7) 0.62 (15.87) 0.75 (19.05) 1.00 (25.4) 1.25 (31.75) 1.50 (38.1) 2.00 (50.8) 38 550 NOTE Specifications in this table are based on a Tri-Clover® clamp 13MHHS, with Buna-N material gaskets at a fluid temperature of 70° F (21.1° C). Other style clamps may produce different pressure ratings. Page 6 September 2013 Product Data Sheet DIMENSIONS Dimension B specifies the most common pickoff type. Actual size may vary depending on pickoff choice. Consult factory for details. AN End Fitting B HEX BODY SQUARE BODY A End Fitting in. (mm) A in. (mm) B (RF) in. (mm) B (MAG) in. (mm) C in. (mm) Size 8-4 8-6 8 10 12 16 20 24 32 0.50 (12.70) 0.50 (12.70) 0.50 (12.70) 0.625 (15.88) 0.75 (19.05) 1.00 (25.40) 1.25 (31.75) 1.50 (38.10) 2.00 (50.80) 2.45 (62.23) 2.45 (62.23) 2.45 (62.23) 2.72 (69.08) 3.25 (82.55) 3.56 (90.42) 4.06 (103.1) 4.59 (116.6) 6.06 (153.9) 3.20 (81.28) 3.20 (81.28) 3.30 (83.82) 3.30 (83.82) 3.40 (86.36) 3.50 (88.90) 3.60 (91.44) 3.80 (96.52) 4.00 (101.6) 2.70 (68.58) 2.70 (68.58) 2.80 (71.12) 2.80 (71.12) 2.90 (73.66) 3.00 (76.20) 3.10 (78.74) 3.30 (83.82) 3.50 (88.90) 1.12 (28.45) Square Body 1.12 (28.45) Square Body 1.12 (28.45) Square Body 1.25 (31.75) Square Body 1.25 (31.75) Square Body 1.63 (41.40) Hex Body 1.88 (47.75) Hex Body 2.25 (57.15) Hex Body 2.75 (69.85) Hex Body NPT End Fitting B HEX BODY SQUARE BODY A End Fitting in. (mm) A in. (mm) B (RF) in. (mm) B (MAG) in. (mm) C in. (mm) Size 8-4 8-6 8 10 12 16 20 24 32 0.50 (12.70) 0.50 (12.70) 0.50 (12.70) 0.75 (19.05) 0.75 (19.05) 1.00 (25.40) 1.25 (31.75) 1.50 (38.10) 2.00 (50.80) 2.70 (68.58) 2.70 (68.58) 2.70 (68.58) 3.29 (83.57) 3.29 (83.57) 3.78 (96.01) 4.23 (107.4) 4.67 (118.6) 5.89 (149.6) 3.20 (81.28) 3.20 (81.28) 3.30 (83.82) 3.30 (83.82) 3.40 (86.36) 3.50 (88.90) 3.60 (91.44) 3.80 (96.52) 4.00 (101.6) 2.70 (68.58) 2.70 (68.58) 2.80 (71.12) 2.80 (71.12) 2.90 (73.66) 3.00 (76.20) 3.10 (78.74) 3.30 (83.82) 3.50 (88.90) 1.12 (28.45) Square Body 1.12 (28.45) Square Body 1.12 (28.45) Square Body 1.25 (31.75) Square Body 1.25 (31.75) Square Body 1.63 (41.40) Hex Body 1.88 (47.75) Hex Body 2.25 (57.15) Hex Body 2.75 (69.85) Hex Body September 2013 Page 7 Precision Turbine Flow Meters Flange End Fitting 2X FLANGES (PER ASME B16.5) ØC B A A in. (mm) B (RF) in. (mm) B (MAG) in. (mm) C—150# Flange in. (mm) C—300# Flange in. (mm) C—600# Flange in. (mm) Size 8-4 8-6 8 10 12 16 20 24 32 5.00 (127.0) 5.00 (127.0) 5.00 (127.0) 5.50 (139.7) 5.50 (139.7) 5.50 (139.7) 6.00 (152.4) 6.00 (152.4) 6.50 (165.1) 3.20 (81.28) 3.20 (81.28) 3.30 (83.82) 3.30 (83.82) 3.40 (86.36) 3.50 (88.90) 3.60 (91.44) 3.80 (96.52) 4.00 (101.6) 2.70 (68.58) 2.70 (68.58) 2.80 (71.12) 2.80 (71.12) 2.90 (73.66) 3.00 (76.20) 3.10 (78.74) 3.30 (83.82) 3.50 (88.90) 3.50 (89) 3.50 (89) 3.50 (89) 3.50 (89) 3.88 (99) 4.25 (108) 4.62 (117) 5.00 (127) 6.00 (152) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 4.62 (117) 4.88 (124) 5.25 (133) 6.12 (155) 6.50 (165) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 4.62 (117) 4.88 (124) 5.25 (133) 6.12 (155) 6.50 (165) Hose Barb End Fitting B 2X MS33658 END FITTINGS C HEX BODY SQUARE BODY A End Fitting A B (RF) B (MAG) C Size in. (mm) 0.50 (12.70) 0.50 (12.70) 0.50 (12.70) 0.625 (15.88) 0.75 (19.05) 1.00 (25.40) 1.25 (31.75) 1.50 (38.10) 2.00 (50.80) in. (mm) in. (mm) in. (mm) in. (mm) 8-4 8-6 8 10 12 16 20 24 32 3.18 (80.77) 3.18 (80.77) 3.18 (80.77) 3.24 (82.30) 3.25 (82.55) 3.56 (90.42) 4.50 (114.3) 5.00 (127.0) 6.50 (165.1) 3.20 (81.28) 3.20 (81.28) 3.30 (83.82) 3.30 (83.82) 3.40 (86.36) 3.50 (88.90) 3.60 (91.44) 3.80 (96.52) 4.00 (101.6) 2.70 (68.58) 2.70 (68.58) 2.80 (71.12) 2.80 (71.12) 2.90 (73.66) 3.00 (76.20) 3.10 (78.74) 3.30 (83.82) 3.50 (88.90) 1.12 (28.45) Square body 1.12 (28.45) Square body 1.12 (28.45) Square body 1.25 (31.75) Hex body 1.25 (31.75) Hex body 1.63 (41.40) Hex body 1.88 (47.75) Hex body 2.25 (57.15) Hex body 2.75 (69.85) Hex body Page 8 September 2013 Product Data Sheet Tri-Clamp End Fitting B 2X TRI-CLAMP END FITTINGS (PER ASME BPE) C A End Fitting in. (mm) A in. (mm) B (RF) in. (mm) B (MAG) in. (mm) C in. (mm) Clamp Size in. (mm) Size 8-4 8-6 8 10 12 16 20 24 32 0.50 (12.70) 0.50 (12.70) 0.50 (12.70) 1.25 (31.75) 1.25 (31.75) 1.50 (31.80) 1.50 (31.80) 1.50 (31.80) 2.00 (50.80) 3.56 (90.42) 3.56 (90.42) 3.56 (90.42) 3.56 (90.42) 3.56 (90.42) 3.56 (90.42) 4.59 (116.6) 4.59 (116.6) 6.06 (153.9) 3.20 (81.28) 3.20 (81.28) 3.30 (83.82) 3.30 (83.82) 3.40 (86.36) 3.50 (88.90) 3.60 (91.44) 3.80 (96.52) 4.00 (101.6) 2.70 (68.58) 2.70 (68.58) 2.80 (71.12) 2.80 (71.12) 2.90 (73.66) 3.00 (76.20) 3.10 (78.74) 3.30 (83.82) 3.50 (88.90) 1.50 (38.10) 1.50 (38.10) 1.50 (38.10) 1.77 (44.96) 1.77 (44.96) 1.99 (50.55) 2.17 (55.12) 2.38 (60.45) 3.18 (80.77) 0.75(19.05) 1.50 (38.10) 2.00 (50.80) High Pressure End Fitting B (Compliant with AS4375) HEX BODY SQUARE BODY A End Fitting A B (RF) B (MAG) in. (mm) C Size in. (mm) 0.50 (12.70) 0.50 (12.70) 0.50 (12.70) 0.625(15.88) 0.75 (19.05) 1.00 (25.40) 1.25 (31.75) 1.50 (38.10) 2.00 (50.80) in. (mm) in. (mm) in. (mm) 8-4 8-6 8 10 12 16 20 24 32 3.25 (82.55) 3.25 (82.55) 3.50 (88.90) 4.00 (101.6) 4.50 (114.3) 4.75 (120.7) 5.50 (139.7) 6.00 (152.4) 7.00 (177.8) 3.20 (81.28) 3.20 (81.28) 3.30 (83.82) 3.30 (83.82) 3.40 (86.36) 3.50 (88.90) 3.60 (91.44) 3.80 (96.52) 4.00 (101.6) 2.70 (68.58) 2.70 (68.58) 2.80 (71.12) 2.80 (71.12) 2.90 (73.66) 3.00 (76.20) 3.10 (78.74) 3.30 (83.82) 3.50 (88.90) 1.12 (28.45) Square body 1.12 (28.45) Square body 1.12 (28.45) Square body 1.25 (31.75) Square body 1.50 (38.10) Square body 1.63 (41.40) Hex body 1.88 (47.75) Hex body 2.25 (57.15) Hex body 2.75 (69.85) Hex body September 2013 Page 9 Precision Turbine Flow Meters METER MODEL NUMBER Cox Precision Turbine Flow Meters - - - - Model Precision Turbine CPT Meter Size 8-4 (1/2" End Fitting, 1/4" Bore) 8-6 (1/2" End Fitting, 3/8" Bore) 8 (1/2" End Fitting, 1/2" Bore) 10 (5/8" End Fitting) 84 86 08 10 12 16 20 24 32 12 (3/4" End Fitting) 16 (1" End Fitting) 20 (1-1/4" End Fitting) 24 (1-1/2" End Fitting) 32 (2" End Fitting) End Fitting Type 37° MS Flare AN NP HP HB TC F1 National Pipe Thread High Pressure Hose Barb Tri-Clamp 150# ANSI Raised Face Flange 300# ANSI Raised Face Flange 600# ANSI Raised Face Flange Bearing F2 F3 Hybrid Ceramic Ball Bearing, Water/Hydrocarbon Service Picko C RF | 2-Pin MS | -250…400° F | RF | 2-FL | -250…400° F | C01 C02 C03 C04 C05 C06 C07 C08 C09 M01 M02 RF | FL | -330…450° F | RTD RF | 3-Pin MS | -250…400° F | Signal Conditioner, IS RF | 3-Pin MS | -40…149° F | Amp, ATEX, IS RF | 3-Pin MS | -40…248° F | Amp RF | 6-Pin MS | -49…284° F | Amp, RTD RF | 6-Pin Micro DIN | -49…284° F | Amp, RTD RF | 3-FL | -40…248° F | Amp MAG | 2-Pin MS | -450…450° F | Sizes 8-4 and 8-6 | 45-55 G MAG | 2-Pin MS | -450…450° F | Size 8…32 | 140-150 G Specials 3-Digit Special Code (Leave blank for non-custom orders.) XXX NN Higher flange ratings and other end fitting types can be provided. Consult the factory for pricing and delivery COX精密渦輪流量計(jì)estimates. Page 10 September 2013 Product Data Sheet CALIBRATION SERVICE NUMBER Flow Dynamics Calibrations - - - - - Calibration Liquid Calibration Fluid Viscosity 1.2 cSt LCAL V1 V2 V3 V4 0.6 … 100 cSt 101 … 300 cSt 301 … 1000 cSt Flow Rate (GPM) 0.003 … 60 F1 F2 F3 F4 61 … 150 151 … 300 301 … 650 Data Points Basic K-Factor 06 10 20 30 10 Points 20 Points 30 Points Number of Viscosity Calibrations 1 Viscosity C1 C2 C3 C4 C5 2 Viscosities (For Calibration Types "M" or "U") 3 Viscosities (For Calibration Types "M" or "U") 4 Viscosities (For Calibration Types "M" or "U") 5 Viscosities (For Calibration Types "M" or "U") Calibration Type Single Viscoisty S M U Multiple Viscosities (For C2…5) Universal Viscosity Curve (For C2…5)) Data Point Spacing Linear LIN Logarithmic LOG Special 3-Digit Special (Leave blank for non-custom orders.) XXX Calibration Service Number Definition Fluid Viscosity represents the fluid viscosity desired. Flow Rate COX精密渦輪流量計(jì)represents process flow rate in gallons per minute. Data Points represents the resolution of the calibration. The more data points that are used, the more accurate the data curve plot. Number of Viscosity Calibrations indicates how many different fluid viscosities are required. Calibration Type • • • “S”represents a calibration that uses only one fluid viscosity. “M”represents a calibration that uses multiple fluid viscosities. “U”represents a calibration that places multiple fluid viscosities in a universal viscosity curve. Data Point Spacing indicates how data points are graphed. Special identifies a design or configuration change that is unique to the calibration.COX精密渦輪流量計(jì)

淮安市瑞泰儀表有限公司 版權(quán)所有 (m.hy-anchor.com)專業(yè)提供CPT84-AN-C-C06COX精密渦輪流量計(jì)等產(chǎn)品信息,歡迎來電咨詢! 返回首頁
網(wǎng)站地圖    蘇ICP備16019275號-1    關(guān)于我們 新聞中心 產(chǎn)品展示 聯(lián)系我們 管理登陸 訪問量:137131 郵箱:2298111344@qq.com

地址:江蘇省淮安市金湖縣園區(qū)
在線客服
電話
86-0517-83308431